How and what are possible Cause of Code P0712

How and what are Possible Cause of Code P0712

 

 

P0712 Transaxle Fluid Temperature Sensor Circuit Low Circuit

 

 

Auto Repair and Component Location

clip_image004

Study Guide and General Description

The automatic transmission fluid(ATF) temperature sensor is installed in the Valve Body. This sensor uses a thermistor whose resistance changes according to the temperature changes. The TCM supplies a 5V reference voltage to the sensor, and the output voltage of the sensor changes when the ATF temperature varies. The automatic transmission fluid(ATF) temperature provides very important data for the TCM’s control of the Torque Converter Clutch, and is also used for many other purposes.

DTC Description

This DTC code is set when the ATF temperature output voltage is lower than a value generated by thermistor resistance, in a normal operating range, for approximately 1 second or longer. The TCM regards the ATF temperature as fixed at a value of 80 °C.

Study Guide and DTC Detecting Condition

Item

Study Guide and Detecting Condition

Auto Repair and Possible Cause

DTC Strategy

● Check for Voltage range

● Sensor signal circuit is short to ground.
● Faulty PCM

Enable Conditions

● Always

Threshold Value

● Voltage < 0.05V

Diagnostic Time

● More than 1 sec

Fail Safe

● Learning control and Intelligent shift are inhibited.
● Fluid temperature is regarded as 80°C

Study Guide and Specification

TEMP.(°C)

RESISTANCE(kΩ)

TEMP.(°C)

RESISTANCE(kΩ)

-40(-40°F)

139.5

80(176°F)

1.08

-20(-4°F)

47.7

100(212°F)

0.63

0(32°F)

18.6

120(248°F)

0.38

20(68°F)

8.1

140(284°F)

0.25

40(104°F)

3.8

160(320°F)

0.16

60(140°F)

1.98

 Auto Repair , Study Guide , Auto Repair , Study Guide , Auto Repair

more trouble and Study Guide